banner



360kw Cummins generator

VERYPOWER Cummins generator set Install Cummins diesel engine with Marathon alternator and Auto-start controller.
Electric capability of VERYPOWER Cummins Generator

Be up to the GB2820.3 & ISO8525 G3 class standard, and meet the requirement of YD/T502- Technical Requirement of Special Cummins Generator for Telecom.
Voltage Regulation(%): Steady state≤±1 Transient state-15~ +20
Frequency Regulation(%):Steady state≤±1 Transient state-7~ +10
Voltage Fluctuation ratio(%): ≤0.5
Frequency Fluctuation ratio(%): ≤0.5
Voltage stabilization time (When the load changes suddenly): ≤1S
Frequency stabilization time (When the load changes suddenly): ≤3S
Waveform Distortion(%): ≤5
Radio interference Suppression: Be accordant with the standard of VDE0875-N Class & GB2820
To meet the customer need, we can also provide 60Hz generator set which is accordant with the International regulation.

Diesel Engine

Stroke: 6-16
Combustion system: Direct spray or Electronic spray
Start: DC start
Cooling: Coolant radiator with fan

AC Generator

Structure Characteristics: Single bearing, automatic voltage regulation(AVR)
Excitation: Brushless & self-excited
Insulation: H grade
Level of protection: IP 21 or IP 23

Control Box

Manual/Automatic start & stop controller
Various Monitor Meter and Optional Switch
Remote control interface and Remote monitor/Remote Sense/Remote Meter (Optional)
MCCB for Short circuit & Overload (optional)
High water temperature alarm, Low oil pressure alarm, Over speed alarm and other kind of alarm

Standard scope of supply

Cummins Generator include:
Diesel engine(with all standard accessories, filters and electric system)
Radiator (with water tank and fan)
Alternator
Control panel
Steel base frame
All above parts are assembled into a whole.

Other standard parts:

Effective muffle
Exhaust elbow
Belows
Storage battery and connection wires
Shock absorber
Technical documents

Optional choice: Different types Generator
1.
Soundproof, weatherproof, automobile, trailer etc;
2
Alternators: Stamford, Marathon, Leroy Somer, Siemens etc
3
Control box: Manual control box, Automatic control box, Remote control box, ATS control box, Parallel or synchronous control box for your choices;
4
Frenquency: 50HZ , 60HZ
5
Voltage: 110V~13.8KV
6
Prime use or Standby use or Continuous use


Note:
1. The above data is only for the customers reference.
2. Those above data are for 50Hz, 1500 rpm, 400V/230V, 3 phases 4 wires. Please contact with us if you need 60Hz specification Or else.
3. We reserve the rights to amend the technical specification here without prior notice.